Mediselect II MS25 oxygen regulator in the O2 version has a G3/4 inlet and a G3/8 (AGA) outlet. The inlet pressure can be up to 300 bar, and the nominal outlet pressure is 4 bar. The flow is set with the flowmeter knob on the scale: 0; 1; 2; 3; 4; 5; 6; 7; 9; 12; 15; 25 l/min.
The pressure gauge rotates, so the reading does not depend on which side the person operating the equipment is standing. The outlet rotates through 360°, which lets you adjust the position of the nasal cannula or face mask and avoid twisting the tubing. The body is made of nickel-plated brass, the adjustment knob of polyamide, the seals are EPDM O-rings, and the system contains a sintered bronze filter. The pressure gauge has a TPE (thermoplastic elastomer) cover.
Why Mediselect II MS25 oxygen regulator?
Choosing a regulator starts with the flow scale. In addition to the successive settings from 0 to 25 l/min, this model has extra settings: 7 l/min is intended for nebulising medication, and 25 l/min for resuscitation. There is no need to work out an intermediate setting when one of these flows is required. Mediselect II MS25 oxygen regulator has a rotating pressure gauge, so the readings can be seen from different sides.
The regulator is a class IIb medical device, and its compliance covers the standards EN ISO 10524-1 and EN 1789 as well as MDR 2017/745. This lets you check whether the parameters of the equipment meet the requirements of your team or facility. Mediselect II MS25 oxygen regulator has an outlet that rotates through 360°, so you can position the nasal cannula or face mask without twisting the tubing.
Rules for using an oxygen regulator
An oxygen regulator is specialist equipment operated by a trained person. Before connecting, check that the connections are compatible: G3/4 inlet, G3/8 (AGA) outlet. Read the pressure from the gauge, rotate it so the readings are clearly visible, and position the outlet so that the tubing of the cannula or mask does not become twisted. Set the flow with the knob in line with the procedures you work to. The Mediselect II MS25 oxygen regulator has a nickel-plated brass body and a sintered bronze filter.
Oxygen equipment is only the next step. In every situation, first make sure you are safe and assess the condition of the casualty, then call for help on 999 or 112. Refresh these rules in the articles Assessing the casualty and Emergency number 112 and calling for help.
Frequently asked questions (FAQ)
What connections does this regulator have?
The inlet is G3/4 and the outlet is G3/8 in the AGA standard. The outlet rotates through 360°.
What pressure does the regulator handle?
The inlet pressure is up to 300 bar, and the nominal outlet pressure is 4 bar.
What standards and class does the regulator have?
The regulator complies with the standards EN ISO 10524-1 and EN 1789 and with MDR 2017/745. It belongs to class IIb.