EZ-IO t.a.l.o.n. intraosseous needle

EZ-IO t.a.l.o.n. intraosseous needle is a handheld device for intraosseous (IO) access that allows insertion at seven sites: the sternum, both proximal humeri, and both proximal and both distal tibiae.

Intraosseous access allows fluids and medicines needed for resuscitating a casualty to be given quickly, and it requires no additional equipment. Order from the Ratowacze Shop!

  • Seven insertion sites – the sternum, both humeri (proximal ends) and both tibiae (proximal and distal ends) give a wider choice of access site.
  • Intraosseous (IO) access – allows fluids and medicines needed for resuscitating a casualty to be given quickly.
  • No additional equipment needed – the device does not need to be supplemented with other equipment.
  • Training level – the device is designed for Rescuers at every level of training.

1 490,00 zł

Version: EZ-IO T.A.L.O.N.
EZ-IO T.A.L.O.N.EZ-IO

Available on backorder / extended delivery time

SKU: RT-156 Category: Brand:

EZ-IO t.a.l.o.n. intraosseous needle is a handheld device for intraosseous (IO) access. Insertion can be performed at seven sites: the sternum, both proximal humeri, and both proximal and both distal tibiae.

Thanks to intraosseous access, Rescuers working in battlefield conditions can quickly give the fluids and medicines needed for resuscitating a casualty. The device requires no additional equipment and is designed for Rescuers at every level of training.

It is a medical device, and its design meets the recommendations of the Committee on Tactical Combat Casualty Care (CoTCCC) for IO devices. EZ-IO t.a.l.o.n. intraosseous needle allows insertion at the sternum, humerus and tibia.

Why is the EZ-IO t.a.l.o.n. intraosseous needle part of tactical equipment?

Intraosseous access is used to quickly give the fluids and medicines needed during resuscitation of a casualty.

The device offers seven insertion sites: the sternum, both humeri and both tibiae, each at the proximal and distal end. If one site is unavailable, another can be used, and the manufacturer describes the device as meeting the CoTCCC recommendations for IO devices. For wider context on helping with life-threatening bleeding, see the article Massive haemorrhage – first aid.

How to use the EZ-IO t.a.l.o.n. intraosseous needle safely?

This is specialist equipment, so it should be used by a trained person, always in accordance with the instructions for use or the label. Insertion is performed at one of the seven sites specified for this device: the sternum, the proximal humeri, or the proximal or distal ends of the tibiae.

Intraosseous access does not replace the basic actions. First assess safety at the scene and call for help on 999 or 112. For massive bleeding from a limb, apply direct pressure, and if the bleeding is life-threatening, apply a tourniquet.

Frequently asked questions (FAQ)

At how many sites can the EZ-IO T.A.L.O.N. needle be inserted?

Seven: the sternum, both proximal humeri, and both proximal and both distal tibiae.

Is any additional equipment needed for use?

No. Intraosseous access with this device requires no additional equipment.

Who should use this device, and is it a medical device?

Yes, it is a medical device. It is intended for use by a trained person, in accordance with the instructions for use or the label.

Specification
  • Manufacturer: Teleflex Medical
  • Code: RT-156
  • Insertion sites: sternum, proximal humeri (both sides), proximal and distal tibiae (both sides)
  • Type: handheld device for intraosseous (IO) access
  • Safety: This is a medical device. Use it in accordance with the instructions for use or the label.
Scroll to Top