SAM IO intraosseous needle stabiliser IO740 (IO740) is a component of the SAM IO intraosseous access system. It has a cylinder-shaped design whose purpose is to protect the catheter from displacement. It is intended for SAM IO intraosseous needles.
The SAM IO system consists of: a driver, needles in three sizes (15 mm, 25 mm and 45 mm), a stabiliser and an adapter. The needles have a diameter of 15 gauge. The stabiliser and the adapter are also available as separate items, so the stabiliser can be treated as a standalone product.
It is a medical device for trained medical personnel. It should be used in accordance with the instructions for use or the label. SAM IO intraosseous needle stabiliser IO740 has a cylindrical design intended to protect the catheter from displacement.
Why the SAM IO intraosseous needle stabiliser?
The IO740 stabiliser has one clearly defined function in the system: its cylindrical design is intended to protect the catheter from displacement. It should not be confused with the IO742 adapter, which attaches to the SAM IO driver and allows alternative intraosseous needles to be used. SAM IO intraosseous needle stabiliser IO740 is a component of a system that includes 15 mm, 25 mm and 45 mm needles and the IO742 adapter.
The choice of needle length (15 mm, 25 mm or 45 mm) depends on the patient's age and physiology, as well as on the protocol and clinical assessment. The insertion sites listed are the proximal humerus, the proximal and distal tibia, and, in children, the distal femur. The SAM IO system is not intended for use in the sternum.
Rules for using the IO740 stabiliser
The stabiliser is part of a system intended for trained medical personnel. It is used in accordance with the instructions for use or the label, and decisions on needle selection and insertion site are made by a trained person, according to protocol and clinical assessment.
A person without medical training should not establish intraosseous access on their own. In a life-threatening situation, make sure the area is safe and call for help on 999 or 112. You can read more about calling for help in the article Emergency number 112 and calling for help.
Frequently asked questions (FAQ)
What is the IO740 stabiliser used for?
It has a cylindrical design intended to protect the catheter from displacement. It is intended for SAM IO intraosseous needles.
Is the stabiliser part of the SAM IO system?
Yes, the system includes a driver, 15 mm, 25 mm and 45 mm needles, a stabiliser and an adapter. The stabiliser is also offered as a separate item.
Who can use this device?
It is a medical device for trained medical personnel, used in accordance with the instructions for use or the label.