Mindray BeneHeart C2 AED defibrillator is a semi-automatic defibrillator with a 7″ LCD display and a CPR Navi compression sensor, designed to help in sudden cardiac arrest. Mindray BeneHeart C2 AED defibrillator guides the user through each stage of the rescue with voice prompts, visual instructions and animations on the screen.
ResQNavi™ technology adjusts the level of instructions to the situation and the user's skills, so the device supports both people with no medical experience and trained Rescuers. The CPR Navi sensor uses two types of sensors, acceleration and pressure, and assesses the depth of compressions, their rate and chest recoil. It gives feedback by voice and image in real time.
ECG analysis takes about 5 seconds, and the energy of the biphasic pulse reaches up to 360 J. In the semi-automatic version, the device indicates that defibrillation is needed and the user presses the shock button. The device is designed for use with adult and paediatric pads with a CPR sensor, and the mode is changed with a simple adult/child switch. Mindray BeneHeart C2 AED defibrillator analyses the heart rhythm in about 5 seconds and prepares the pulse for the shock.
Why choose the Mindray BeneHeart C2 AED defibrillator?
In cardiac arrest, every pause in compressions matters. QShock™ technology makes it possible to deliver the first shock in less than 8 seconds, and the short rhythm analysis limits interruptions during the rescue. The AED defibrillator Mindray BeneHeart C2 combines this with an assessment of CPR quality, so the user can see and hear whether compressions are deep enough and at the right rate.
The device can be configured for up to 3 languages, and daily automatic self-tests check its condition. IP55 resistance means protection against dust and water, and the operating temperature range is from -5°C to 50°C. You can find other models in the AED defibrillators.
Rules for using an AED in practice
First assess the safety of the scene, then check the casualty's response and breathing. If the casualty does not respond and is not breathing normally, call for help on 999 or 112, ask someone to bring an AED and start chest compressions. A casualty's survival may depend on a bystander taking action. After switching the device on, follow the voice and on-screen instructions, and before use make sure the adult/child mode switch is set correctly.
The shelf life of the battery and pads is 5 years from the date of manufacture, so it is worth checking the date and the self-test messages. You can read more about operating the device in the article Chapter VIII – Automated external defibrillator (AED).
Frequently asked questions (FAQ)
Is the BeneHeart C2 semi-automatic?
Yes. The device indicates that defibrillation is needed, and the user presses the shock button.
What does the CPR Navi sensor assess?
The depth and rate of compressions and the chest recoil after each compression. Feedback is given by voice and image in real time.
Can it be used on a child?
The device has an adult/child mode switch and adult and paediatric pads with a CPR sensor.