AED defibrillator Mindray BeneHeart L1 with CPR Navi compression sensor is a compact AED measuring 196 × 191 × 65.5 mm. It starts when the cover is opened and gives the following steps by voice and on a 1.96" LCD screen with a resolution of 240 × 64 pixels. Start-up time is under 2 s. Prompts can be switched between up to 3 languages.
The device uses a biphasic BTE waveform. The energy range is 100–360 J for adults (default 200–300–360 J) and 10–200 J for children (default 100–100–200 J). ECG analysis takes under 5 s, the pause before the shock is also under 5 s, and the patient impedance range is 25–300 Ω. You can quickly switch between adult and child mode.
The electrodes are pre-connected and single-use, and the battery provides years of standby and many hours of operation. Electrode expiry, battery type and capacity are in the “Additional information” tab.
AED defibrillator Mindray BeneHeart L1 allows you to choose 30:2, 15:2 or compression-only CPR mode.
Why the AED defibrillator Mindray BeneHeart L1 matters during CPR
QShock™ Plus technology prepares the device for defibrillation while the heart rhythm is still being analysed. Pre-charging helps reduce pauses in chest compressions and shorten the time to the next shock. With MR66 electrodes with a CPR sensor, the CPR Coach function gives ongoing information on compression depth and rate. ResQNavi™ guides the user through the successive rescue actions, and the CPR metronome helps maintain the pace. The available modes are 30:2, 15:2 and compression-only. AED defibrillator Mindray BeneHeart L1 can optionally communicate with the AED Alert™ 2.0 system via Wi-Fi or a 4G network.
The device monitors its own condition with regular self-tests, and a visual indicator lets you check that it is ready for use. Communication with the AED Alert™ 2.0 system via Wi-Fi or a 4G network is optional. You will find other models in the AED defibrillators. IP55 ingress protection and resistance to drops from 1.5 m are parameters of the AED defibrillator Mindray BeneHeart L1.
Rules for using an AED during CPR
First make sure the scene is safe, check the casualty's response and breathing, call for help on 999 or 112 and start chest compressions. When an AED is available, open the cover, which starts the device, and follow the voice prompts. For a child, switch to child mode.
A bystander taking action can determine the casualty's survival. How to work with the device is described in the article Chapter VIII – Automated external defibrillator (AED).
Frequently asked questions (FAQ)
How do I start this AED?
Simply open the cover. The device switches on in under 2 s and guides the user with voice prompts and on-screen instructions.
Does the device have a child mode?
Yes, you can quickly switch between adult and child mode. For children the energy range is 10–200 J, and the default values are 100–100–200 J.
How long do the battery and electrodes last?
The 4200 mAh Li/MnO₂ battery has a standby life of 5 years under the conditions specified by the manufacturer. The electrodes are pre-connected and single-use, with a shelf life of 5 years from the date of manufacture.